Executes a six-question forcing interrogation based on FDA 21 CFR 820 (QSR/QMSR) to assess audit readiness, covering complaints/MDR, process validation, DHRs, CAPAs, labeling, and Form 483 history. It generates a structured compliance report with a readiness verdict and prioritized corrective actions.
Say it in your own words; the assistant finds this recipe by itself. Examples:
Use this skill when preparing for an FDA inspection, conducting an annual internal QSR audit, or responding to a Form 483 or Warning Letter. It is also appropriate when making decisions about recalls or evaluating QSR posture before submitting a 510(k) or PMA. It is specifically designed for US medical device manufacturers needing to verify compliance with 21 CFR 820.
Command: /compliance-os:fda-qsr-audit-prep <scope>
The FDA QSR auditor pressure-tests any US medical-device QSR work. Six questions before any internal audit, FDA inspection, Form 483 response, or recall decision.
21 CFR 820.198 + 21 CFR 803 — most-cited FDA inspection area. - Complaint log complete: who / what / when / device / batch - Investigation closure within reasonable timeline - MDR-reporting decision tree applied: death OR serious injury OR malfunction-that-could-cause = MDR - 30-day timeline for most MDR reports; 5 days for certain serious events - Complaint trending input to management review
Cross-walks ISO 13485 Clause 7.5.6 (substantially harmonized post-Feb 2026). - Initial validation at process introduction - Revalidation triggers: process / equipment / material change OR periodic schedule - Statistical techniques per 21 CFR 820.250 where applicable - Cross-check with cs-cqm-iso13485 for ISO 13485 alignment
21 CFR 820.180 — 2-year retention from commercial distribution; check sampling for completeness. - Device History Record (DHR) for each unit/lot/batch - Must include: dates of manufacture, quantity manufactured, quantity released, acceptance records, primary identification label, device identification, control number - Sample stratified by product class - Verify DHR closeness to DHF (design history file)
21 CFR 820.100 = ISO 13485 8.5.2 substantially harmonized. - Root cause analysis depth (5 Why minimum) - Effectiveness verification = measurable evidence, not "we updated the procedure" - Containment / correction / corrective action distinction documented - Closure approval by appropriate authority - Aging CAPAs > 90 days flagged
FDA-specific overlay not in ISO 13485. - Labeling per 21 CFR 801 requirements - For specific device types: also 21 CFR 800 series sectoral overlays - UDI (Unique Device Identification) per 21 CFR 830 - Promotional materials reviewed for accuracy + non-misleading
Form 483 = FDA observation; not equivalent to ISO nonconformity. - Response within 15 working days - Each observation has documented corrective + preventive action with timeline - Effectiveness verification evidence - For Warning Letters: separate response track + potentially FDA meeting
# 1. QSR compliance posture
python ${CLAUDE_PLUGIN_ROOT}/vendor/ra-qm-team/fda-consultant-specialist/scripts/qsr_compliance_checker.py compliance_state.json
# 2. FDA submission tracking (510(k) / PMA / IDE)
python ${CLAUDE_PLUGIN_ROOT}/vendor/ra-qm-team/fda-consultant-specialist/scripts/fda_submission_tracker.py submissions.json
# 3. HIPAA overlap (if connected device handles PHI)
python ${CLAUDE_PLUGIN_ROOT}/vendor/ra-qm-team/fda-consultant-specialist/scripts/hipaa_risk_assessment.py phi_inventory.json
# 4. Mock FDA inspection
python ../../skills/compliance-os/scripts/audit_simulator.py fda_qsr_scope.json
# FDA QSR Audit Prep: <scope>
**Date:** YYYY-MM-DD
## The Decision Being Made
[programme-plan | inspection-readiness | 483-response | MDR-decision | recall]
## Complaint + MDR Posture
- Complaints last quarter: N
- MDR-reportable events: M
- MDR reports filed within timeline: % (target 100%)
- Complaint trending review at management level: yes/no
## Process Validation Status (21 CFR 820.75)
- Validations on schedule: %
- Stale validations: <list>
- Statistical techniques applied: yes/no per process
## DHR Completeness (21 CFR 820.180)
- DHRs sampled: N
- Completeness rate: %
- 2-year retention compliant: yes/no
- Stratified by product class: yes/no
## CAPA Health (21 CFR 820.100)
- CAPAs sampled: N
- Root cause analysis depth: adequate/inadequate
- Effectiveness verification: complete/incomplete
- Aging CAPAs > 90 days: N
## Labeling (21 CFR 801)
- Recent products reviewed: <list>
- Labeling accurate + non-misleading: yes/no
- UDI compliance per 21 CFR 830: yes/no
## Form 483 / Warning Letter History
- Form 483s last 3 years: N (each: closed/in-progress)
- Warning Letters last 5 years: N (each: closed/in-progress)
- Pattern across observations: <thematic>
## ISO 13485 Cross-Walk (post-Feb 2026 harmonization)
- ISO 13485 audit findings: <link to cs-cqm-iso13485 output>
- FDA-specific overlays remaining: labeling + complaint handling + MDR reporting + recall procedures
- Cross-framework reuse: % of evidence shared
## Verdict
🟢 INSPECTION-READY | 🟡 GAPS-IDENTIFIED | 🔴 NOT-READY
## Top 3 Actions
[3 concrete next steps with owner + FDA-cited timeline (15 days / 30 days / etc.)]
## Outside Counsel Required
[For Warning Letter response, recall decisions, or 510(k) / PMA strategy disputes]
/compliance-os:compliance-readiness — for multi-framework view/compliance-os:iso13485-audit-prep — for ISO 13485 cross-walk pair (substantially harmonized)/compliance-os:gdpr-audit-prep — if connected device handles personal data/c-level-agents:gc-review — for Warning Letter response coordinationcs-fda-qsr-auditorfda-consultant-specialist../iso13485-audit-prep/, ../compliance-readiness/Version: 1.0.0
LICENSESKILL.mdVendored from alirezarezvani/claude-skills, commit 27cfcd0fb0a4, path compliance-os/skills/fda-qsr-audit-prep, licence MIT. The upstream licence file ships inside the skill.